Sabtu, 26 November 2011

Cast Resin Transformers LS







Introduction
Great progress has been made in the development and improvement of
distribution transformers over the last decades.
The application of high quality insulation material and suitable selection of the coil
structure for high stress have contribute to the development of LS CAST RESIN
Transformers.
The LS CAST RESIN Transformer has succeeded in combining the advantage
of oil-filled and conventional dry type transformers, which are fabricated with an
epoxy resin. The windings are completely embeded under vacuum conditions.
This casting method makes it possible to assure void-free epoxy penetration of
both the inner layer and turn to turn insulation.

Environmentally safe
LS CAST RESIN Transformers will not emit oil or toxic
gases into the atmosphere. Therefore, they do not pollute
the environment and are strongly recommended as a
replacement for askarel(PCB)-filled transformers.

Moisture proof
The complete casting of coils under vacuum prevents the
penetration of moisture into the winding.
Therefore, it is suitable for both storage and operation in
harsh environment and is capable of being switched on
immediately after such storage without pre-drying.

No partial discharge
There is no possibility of partial discharge in LS CAST
RESIN Transformers.
Whole core & coil is tested to guarantee the life expectancy
of the insulation system.
LS CAST RESIN Transformers are free of partial discharge
at least up to 1.2 times of the rated voltage.

Low noise
The coating of the core with an epoxy resin have lead to an
appreciable noise reduction. Noise is also reduced due to
the sound suppresing effect of the step lap cutting.

High overload capability
Based on the high thermal time constant factor of the
windings, LS CAST RESIN Transformers can be overloaded
for a short duration considerably higher than oil-immersed
transformers. It has a greater capability to withstand sudden
high overloads such as might be encountered in heavy
traction applications.

High impulse strength
LS CAST RESIN Transformers are very resistant to impulse
voltage.
Impulse withstand levels to 200kV are available because of
careful design and special structure.

Maintenance free
Maintenance is almost completely eleminated. No checking
of liquid level and no dielectric test for moisture absorption is
required.
Due to the smooth coil surface, heavy dirt and dust build up
is eleminated even under the worst circumstances.
The recommended routine maintenance is an occasional
visual inspection.

Fire resistant
LS CAST RESIN Transformers have a very excellent
characteristic of self fire-extinguishing and fire resistance.
So there would be no fear of spread of fire even if fire took
place around the electricity room

LS CONTACTOR and OVERLOAD RELAYs METASOL


Designed to show superior technology:
The Metasol series
Sealed structure has improved its safety features so that
no arc flash is exposed. In order to emphasize its
durability as an industrial device, Metasol series adopt
simple design form and sophisticated shape applying
diamond cut concepts on product surface.



Contactor 18AF
MC-6a, 9a, 12a, 18a
Rated current: 6, 9, 12, 18A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-12
Current range: 0.1~18A
Trip class: Class10, 20


Contactor 22AF
MC-9b, 12b, 18b, 22b
Rated current: 9, 12, 18, 22A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-32
Current range: 0.1~40A
Trip class: Class10, 20

Contactor 40AF
MC-32a, 40a
Rated current: 32,40A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-32
Current range: 0.1~40A
Trip class: Class10, 20

Contactor 65AF
MC-50a, 65a
Rated current: 50, 65A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-63
Current range: 4~65A
Trip class: Class10, 20

Contactor 100AF
MC-75a, 85a, 100a
Rated current: 75, 85, 100A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-95
Current range: 7~100A
Trip class: Class10, 20

Contactor 150AF
MC-130a, 150a
Rated current: 120, 150A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-150
Current range: 34~150A
Trip class: Class10, 20

Contactor 225AF
MC-185a, 225a
Rated current: 185, 225A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-225
Current range: 65~240A
Trip class: Class10, 20

Contactor 400AF
MC-265a, 330a, 400a
Rated current: 265, 330, 400A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-400
Current range: 85~400A
Trip class: Class10, 20


Contactor 800AF
MC-500a, 630a, 800a
Rated current: 500, 630, 800A
Rated insulation voltage: 690V
TypeⅡ: 150kA @415V Max.
Overload relay MT-800
Current range: 200~800A
Trip class: Class10, 20

LS BUSDUCT



Introduction
1.1 High Quality & Reliable Power Distribution System


High Current Density
LS BusDuct can carry up to 7500A with reduced loss.
It is ideal for both high-rise buildings and industrial
applications, and performs with a safe, flexible, reliable
and economical efficiency.
The simplified design of the LS BusDuct system
allows for easy routing, extension, relocation,
replacement and maintenance of power loads.
These features are well suited to the needs modern
architecture.


Service Conditions
Ambient temperature : -15 C ~ 55 C
Relative humidity : 95% or below

Bus Bar
Copper bus bars have a conductivity of 99% or more.
Aluminum bus bars have a conductivity of 61% or more.
Electrical contact surfaces are:
- Tin-plated : (copper bus duct)
- Silver-plated : (aluminum bus duct)
The plating reduces contact resistance and prevents
contact surface corrosion.

Temperature Rise Stability
Temperature rise limits are within 55 C or less on the
external duct surface, as specified in IEC 60439-1, -2.


Insulation Properties
Class B (130 C) is applied to the conductors. Epoxy,
PET and mica (1200 C, for fire resistance) are available
options.
FRP (fiber reinforced plastic) is used as a spacer between
conductors or between the conductor and the duct housing.
These insulating materials have very high dielectric properties.
LS BusDuct systems are rated up to 1000V service capacity.

Lower Voltage Drop & High Short-
Circuit Ratings
Because of the extremely low impedance, the resultant
voltage drop is also low.
The effective design allows power to be delivered with
the greatest possible efficiency.
LS BusDuct also has a very high shortcircuit with stand
strength.
This ensures LS BusDuct can be safely applied in
commercial and industrial environments.

Reference Project 

  • Tahun 2010

  1. OPP Line 6 Argha Karya, Jakarta

  • Tahun 2011

  1. Ciputra World, Surabaya 
  2. Jakarta Eye Center 
  3. St. Moritz - Ambasador Tower, Puri-Jakarta 
  4. ASMO INDONESIA. Kawasan Industri Cibitung- Jawa Barat

  • Tahun 2012

  1. Jayapura Mall (Irian Mall) ,Jayapura-Papua Island Indonesia Timur
  2. YTK, Kawasan Industri Cibitung 
  3. Alam Sutra Office, Tangerang-Banten 
  4. ASMC Indonesia, Cibitung 
  5. Toshiba, Kawasan Industri Cikarang
  6. Sanko Gosei Industrial, Indonesia 
  7. Holiday INN, Pluit-Jakarta 
  8. Sugity, Kawasan Industri Cibitung
  9. Ngurah Rai Airport, Bali
  10. Cyber Data Center, Jakarta
  11. Juanda Airport, Surabaya 
  12. Hankook Tire-Cikarang
  13. Krakatau POSCO Integrated Steel Mill Cilegon

  • Tahun 2013

  1. Dowa Termotech, Karawang 
  2. PT. Polychem Indonesia Tbk.
  3. Grage Mall, Cirebon 
  4. Fave Hotel Jakarta
  5. Ngurah Rai Airport Phase 1. (Additional), Bali
  6. Ngurah Rai Airport Phase 2. (Additional), Bali
  7. Ngurah Rai Airport Phase 3. (Additional), Bali
  8. Green Bay Pluit Mall, Jakarta
  9. Krakatau POSCO, cilegon
  10. Blast Furnace.
  11. Honda Precision Parts Manufacturing (HPPM). Cikampek
  12. NOBLE House, Jakarta
  13. St. Moritz Mall (Puri Village Mall). Jakarta
  14. RFCC-Pertamina Cilacap
  15. Green Bay Condotel, Jakarta
  16. Auto ASKA Indonesia, Karawang
  17. MORIROKU TECHNOLOGY, Karawang
  18. Juanda Airport Phase 2, surabaya
  19. IKEA Alam Sutra, Tangerang
  20. Satrio Office Tower, Jakarta
  21. Galery West, Jakarta
  22. Metropolitan Tower, Jakarta
  23. Menara Sentraya, Jakarta
  24. MNC News Center, Jakarta
  25. Samarinda Mixed Used, Samarinda-Kalimantan
  26. SKYLINE Building, Surabaya
  • Tahun 2014
  1. CYBER 1 Extension ,Jakarta
  2. Delta Maribaya, Cikarang
  3. Tokai Rubber, Cikarang
  4. Hekikai Indonesia, Cibitung
  5. MNC TV, Jakarta
  6. GLOBAL TV, Jakarta
  7. Indonesia International Expo(IIE), Jakarta
  8. Ngurah Rai Airport-Domestic Terminal, Bali
  9. Menara Sentraya(Genset), Jakarta
  10. Honda Precision Part Manufacturing (HPPM), Phase 2, Cikampek
  11. Terminal 3 ULTIMATE Seokarno Hatta International Airport, Jakarta
  12. Alila SCBD, Jakarta
  13. Hokan Indonesia Ciawi, Jabar
  14. Semarang Autocomp Indonesia, Jepara
  15. CYBER CSF Expansion, Jakarta
  16. ASTRA DAIHATSU MOTOR Casting, Karawang
  17. Global Tv (Chiller),Jakarta
  18. Satrio Tower Office(Genset) , Jakarta
  19. Centennial Tower ( genset), Jakarta
  20. Bahana Tower, Jakarta
  21. CYBER 2 Tower, Jakarta