Sabtu, 18 Februari 2012

Vacuum Circuit Breaker

Vacuum Circuit Breaker
Lateral type



Lateral type
24/25.8kV 16kA 630A
● Rating: 24/25.8kV 16kA 630A
● Rated short-circuit withstand characteristics: 3 sec
● Rated breaking time: 3 cycle
● Rated operating sequence: O-0.3s-CO-3m-CO
● Type test level: M1, E1, C1
● Compact size switchgear (Lateral type)
● Control voltage
- DC 24V, DC 48V, DC 110V, DC 125V, DC 220V
- AC 48V, AC 110V, AC 220V
● Standard and certification
- IEC 62271-100
- KERI certified

Kamis, 16 Februari 2012

Oil Immersed Transformer

Oil Immersed Transformer
Compact Type, Environment-Friendly Type




Leading transformer manufacturer that has provided total solution for power generation system!
There is nothing like LSIS for Oil Immersed Transformer as well.


It may seem to go unnoticed but the LS Oil Immersed
transformer takes the environment of consumer energy into serious consideration.
As an insulation media that use insulation oil, the LS Immersed Transformer has been newly
desinged to optimize the working environment in order to reduce noise with the use of non-aging,
cold rolled, high permeability, grain oriented silicon steel.


Innovation
Highly recognized with the largest manufacturing
capacity as well as No.1 market share in domestic market,
the LS Transformer is seeking globalization with a new conceptual
transformer that greatly improve in common envirovement environment and reduction of loss
along with unpatrolled stability.




















Vacuum Circuit Breakers

Vacuum Circuit Breakers
Pro-MEC


PT. Duta Listrik Graha Prima as the sole distributor of LS Industrial Systems inIndonesia. Latest VCB issued by LS (LG) is the following type Vacuum CircuitBreaker some data could be disclosed.
Vacuum Circuit Breaker
LSIS Pro-MEC VCB is user-friendly to give more convenience
and safety by providing high speed interrupting time (3cycles),
adopting the rapid auto-reclosing method, and having
wide range of accessories.

Wide range of accessories (optional)

􀓋 Key Lock
􀓋 Padlock of earthing switch
􀓋 Button padlock
􀓋 Position switch of the earthing switch
􀓋 Button cover
􀓋 Locking coil of earthing switch
􀓋 Position switch (Cell switch)
􀓋 Shutter padlock
􀓋 Preparatory trip coil (Secondary trip coil)
􀓋 MOC (Mechanically operated cell switch)
􀓋 Latch checking switch
􀓋 TOC (Truck operated cell switch)
􀓋 Charge indicator
􀓋 Code plate (Miss insertion prevention)
􀓋 Position padlock
􀓋 Capacitor trip device
􀓋 Earthing switch Note 1)
􀓋 Rectifier
Note 1) The earthing switch is not available for 17.5kV VCB.



High reliability of the operating mechanism
- Separate design of the main circuit from the
operating mechanism.
- Adopt the toggle link method.
- Improved the reliability of electric circuit.
- Adopt the rapid auto-reclosing method as a
standard option. (O-0.3sec.-CO-3min.-CO)

High interrupting performance


􀓋Make short of the interrupting time. (3cycles)
􀓋Increase the rated short-circuit withstand
   characteristics. (1sec. to 3sec.)

Great operational safety

􀓋Reinforce the insulation in the conduct, by adopting the
   molded housing in each phase.
􀓋Built in the device making the contacts open first when
   draw in and out.
􀓋Adopt the tulip-shape connection between the cradle and
   the VCB.














VCB
Pro-MEC 
MCSG (Metal Clad Switchgear) 


Features
􀓋Module type VCB
􀓋Convenient especially for fabricating MCSG
- Housing is designed like VCB compartment style
- MCSG panel can be easily constructed if combined with Low voltage compartment, Busbar
compartment and Cable compartment.
􀓋Convenient for maintenance and offering high safely
- Earthing switch can be operated from outside of the panel, and which makes earthing of 3 phases at the
same time.
- Without opening the compartment panel door, breaker can be drawn in or out electrically or manually
􀓋Main functions
- Breaker : draw- in or out electrically or manually
- Compartment : 3-positions
􀓋Standard
- IEC 62271-100
































































Rabu, 15 Februari 2012

VCS (Vacuum Contactor Switch)


Vacuum Contactors Switch (VCS)
Medium Voltage LS




LS Vacuum Contactors Switch

We have the major technology that others can not catch up.
LS vacuum contactors provide high withstand-current strength and
switching capacity as well as versatile auxiliary functions.

LS medium voltage vacuum contactors using LS vacuum interrupters manufactured
with worldclass technology are type tested in LS PT & T that is accredited high power
test lab by worldclass KOLAS.



LS Tri-MEC vacuum contactors are mainly used for the switching of motors,
transformers, capacitors in AC power lines. They can be installed in multi-stack
cubicles.
A vacuum contactor comprises several assemblies such as switching mechanism
including vacuum interrupters, magnetic actuator, high strength molded front
cover and auxiliary devices. Stable and high operating cycle is executed by the
vacuum interrupters made of high alumina ceramic tube which makes it possible
to degas in a high temperature with excellent mechanical strength.
Actuating is available either at instantaneous or continuous excitation. Functions for
safety in connecting and disconnecting are also provided.

Operation conditions
Ambient temperature : -5 to 40℃
Maximum temperature of 24-hour mean : 35 ℃
Altitude : 1000m
Humidity : 24-hour measured average - max. 95% RH
1 month measured average - max. 90% RH
Applied standards
IEC Pub. 60470, IEC 60282-1, JEM 1167, KEMC 11

Up-graded performance

Rated short-time current 6.3kA

[ 6.3kA ]
Performance is up-graded to rated short-time current 6.3kA/1sec.
and switching capacity 4kA according to IEC60470.

Short-circuit protection
[ 40kA ]
Power fused type vacuum contactors, in-house tested according to IEC 60282-1,
can provide short-circuit protection up to 40kA.

High performance, high reliability
and long service life
LS vacuum interrupters that comply with
IEC, ANSI and NEMA standards are
manufactured by the process of brazing
and degasing together in a high
vacuum furnace to assure high reliability.

Superior mechanical strength and
degasing
Providing long service life and suited for
frequently operating purpose due to
using high alumina ceramic tube and
degasing in a high temperature.

High speed interruption and short
arcing time
It has fast recovering characteristic of
vacuum insulation. When opening it
breaks the current at the first current-zero
point to minimize the wearing of
contacts.

Reliable interruption of fault current
LS current limiting power fuse can protect
the devices and systems from fault current
by interrupting within half cycle.
High current such as short-circuit current
cause a fuse blown out due to the
reaction on the material inside of a fuse
within such a short time.

Applied standards
IEC 282-1, DIN 43625, BS 2692, KSC 4612










MCB (Miniatur Circuit Breakers)


Miniature Circuit Breakers 
&
Residual Current Devices


BKN / BKN-b / BKN-c / BKH / BKP / BFN /
RKN / RKN-b / RKS / RKS-b / RKP / 32KGR


What is RoHS?
The RoHS (Restriction of Hazardous Substances) is an EU
Directive that specifically identifies six key materials so that
manufacturers are held responsible for ensuring that their
products contain controlled concentrations of the six
substances restricted by the Directive.
The Six Hazardous Substances: Below 1,000ppm of Lead
(Pb), Mercury (Hg), Hexavalent Chromium (Cr+6),
Polybrominated Biphenyls (PBB) and Polybrominated Biphenyl
Ethers (PBDE), and below 100ppm of Cadmium (Cd).
▶RoHS : Directive on the Restriction of Hazardous
Substances in the Electronic Equipment (Effective on
February 13, 2003)



Application
Products manufactured by LSIS do not directly apply
to the RoHS Directive.
However, small inverters imbedded in sport equipment
and small breakers in large home appliances can be
indirectly applied to the Directive.
LSIS continues to comply with the RoHS directive
in order to establish environmentally Friendly
management policies and global competitiveness for
our products.
According to the Law, eight of the 10 WEEE products
excluding ‘medical equipment’ and ‘control systems’
must be RoHS compliant.


MCB